Digital acquisition Dymas 24 Master-V
Digital acquisition Dymas 24 Master-V multi-channel seismic acquisition for short and long-term monitoring of civil, industrial and monumental works.
DYMAS 24 MASTER-V
DYMAS24 MASTER-V is a 6-channel acquisition system configurable for event or continuous recordings with all the necessary functionalities to manage single dynamic sensors or complex networks in seismic, microseismic, dynamic monitoring for permanent or temporary installations in dams, buildings or seismic stations.
The acquirer can be supplied with the accessories already pre-wired, inside a single wall or base cabinet.
Multichannel recorder
- Up to 6 channels
- Standard guidelines UNI 4150-3, DIN45669-1, UNI 9916, EN61000 61326-1
- 24 bit multihannel sampling
- 10Hz - 8KHz sample rate
- Dynamic ≥ 130dB @ 100Hz
- Bandwidth DC - 3.2 KHz
- Continuous and/or triggered recording
- Built-in calibration function
- 32 GB internal SD memory
- Seismometers and/or accelerometers connection
- LCD and keyboard membrane
- available MASTER-Vp (plug-in) version with IP65 sealed connectors
Gas reservoir


Seismic and microseismic networks


Bridges and Infrastructure



Applications
- Seismic monitoring
- Platform monitoring
- Pipeline monitoring
Details
Communication system via LAN. The connection to the system can be made remotely via 3G modem, 4G, FIBER OPTIC, WiFi.
It is equipped with LCD display (optional) and membrane keyboard for status display and control function.
The software DYMASOFT, integrated with the data processing software VIBROSOFT or SOLWEB, allows the realization of efficient dynamic monitoring networks of structures according to the reference standards, while the version in continuous recording via miniSEED protocol and SEEDlink transmission for seismic and microseismic monitoring networks.
The DYMAS24 MASTER-V is available in a version with terminal block connections (for fixed installations) or in a version with inputs and outputs with MIL IP65 connectors for temporary installations.
It is equipped with LCD display (optional) and membrane keyboard for status display and control function.
The software DYMASOFT, integrated with the data processing software VIBROSOFT or SOLWEB, allows the realization of efficient dynamic monitoring networks of structures according to the reference standards, while the version in continuous recording via miniSEED protocol and SEEDlink transmission for seismic and microseismic monitoring networks.
The DYMAS24 MASTER-V is available in a version with terminal block connections (for fixed installations) or in a version with inputs and outputs with MIL IP65 connectors for temporary installations.
Technical Characteristics
System
Input Channels | From 1 to 6 sensor channel |
Configuration | Standalone or multi-station network |
Timing | Sampling and Internal RTC synchronized via GPS or remote control - all channels simultaneous sampling |
Triggering Mode | Threshold level and/or STA/LTA, HP filter, selectable for each channel |
Recording Mode | Internal/external or continuous recording with SeedLink Protocol. Software Selectable pre/post-trigger length. Recording of pick values (min-Max), according to DIN 4150 part II, internal selectable from 10 to 100s |
Data Storage | 32 GB internal SD for 6 channel group (till to 64GB optional) or 512 GB with SSD |
Diagnostics | Battery voltage, temperature, sensors test |
Power Consumption | 5W |
Communication | Ethernet TCP/IP - USB2.0 – RS232 (optional) |
File formats | Solgeo EVE, MiniSEED, other on request |
Support Software | Seiscomp3, Antelope, Earthworm and similar |
24 bit module
Converter | Individual 24-bit Sigma/Delta per each channel, with DSP each 6 channels, Integrated digital antialiasing filter |
Input Level | 5Vpp, 20Vpp, differential Input |
Sensor Calibration | Built-in, positive or negative edge |
Sampling | Can be set from 10Hz to 8.000Hz
in EVENT DETECTOR mode 1 (The symbol * next to the value indicates the non-decimated sampling frequencies) Can be set from 10Hz to 1.000Hz in CONTINUOUS mode; |
Bandwidth | DC - 3.200 Hz |
Dynam ic Range | 130 dB@100Hz |
Programmable Gain | 1-2-4-8-16-32-64-128 |
Filter Anti Aliasing | Digital Filter FIR |
Output Data Format | 32 bit signed in user selectable format |
External interfaces
GPS Antenna | GPS time synchronization, RS-422 interface | |
Power | 9VDC to18 VDC (adapter 120/240 V AC optional), automatic turn OFF when battery ‹10,2 V, turn ON ›11,8V | |
Seismic Sensors | Seismometers, Accelerometers Force Balance, ICP, piezoeletrics, MEMS, Geophones. | Extensometer, Termocouples, Hydrophones, Piezometers |
Other Interfaces | USB 2.0 / LAN / RS-232 / Modem ADSL-FO-GSM-GPR-3G / WiFi |
Physical characteristics
Container Features | Metallic cabinet default protection IP65, higher with additional cabinet |
Working Temperature | -20°C, +70°C |
Dimensions (LxWxH) | 300 x 210 x 70 mm |
Weight | 1 Kg |
Umidity | 0-100% non-condensed |
Gallery